Autor: |
Xiang Yan Liu, Xu Dong He, Xiao Bing Dai |
Rok vydání: |
2013 |
Předmět: |
|
Zdroj: |
Applied Mechanics and Materials. 441:805-808 |
ISSN: |
1662-7482 |
DOI: |
10.4028/www.scientific.net/amm.441.805 |
Popis: |
Firstly, this paper introduced infrared detecting and tracking system (IR D&T System) and several commonly used scanning solutions in IR D&T System briefly. Secondly, it analyzed how 2D scanning mirror works and PID (Proportion, Integration and Differentiation) algorithm. Thirdly, it introduced commands format and controlling method of the 2D scanning mirror used in image-spectrum integrated instrument developed by our group. And then it designed controlling software of the 2D scanning mirror using its secondary development package (SDK) and VC++. The software communicates with 2D scanning mirror through serial port. The MSCOMM serial communication control is used in communication software design. The controlling software is integrated to software of image-spectrum integrated instrument successfully and experiment results verified the correctness of controlling algorithm and engineering usability of the software. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|