Popis: |
It has been shown that peri-implant crestal bone reactions are influenced by both a rough-smooth implant border in one-piece, non-submerged, as well as an interface (microgap [MG] between implant/abutment) in two-piece butt-joint, submerged and non-submerged implants being placed at different levels in relation to the crest of the bone. According to standard surgical procedures, the rough-smooth implant border for implants with a smooth collar should be aligned with the crest of the bone exhibiting a smooth collar adjacent to peri-implant soft tissues. No data, however, are available for implants exhibiting a sandblasted, large-grit and acid-etched (SLA) surface all the way to the top of a non-submerged implant. Thus, the purpose of this study is to histometrically examine crestal bone changes around machined versus SLA-surfaced implant collars in a side-by-side comparison. |