Detailed design data package: 3.1a-Film cooler pressure drop data; Item 3.2a - SBS packing selection; Item 3.2b, 3.2c - Pressure drop data for SBS distribution plate; and Item 3.2e - SBS distribution plate and liquid risers. PHTD pilot-scale melter testing system cost account milesonte 1.2.2.04.15A

Autor: J. Evans, L.D. Anderson, G.A. Whyatt
Rok vydání: 1996
Předmět:
DOI: 10.2172/212722
Popis: This data package transmits information collected on the Liquid-Fed Ceramic Melter (LFCM) offgas system prior to melter feeding operations. Injection of steam to the melter plenum was used to simulate feeding of the melter. Steam surge cases were studied under steady-state surge conditions. Dynamic surges will be examined under data needs. The Fluor data needs included two blank tables requesting specific information for data needs 3.1 and 3.2. These tables are provided in Tables S.1 and S.2 below with the requested information filled in.