Simultaneous removal of NO and SO2 in packed scrubbers or spray towers
Autor: | Kevin Smith, Peter Harriott, Lewis B. Benson |
---|---|
Rok vydání: | 1993 |
Předmět: | |
Zdroj: | Environmental Progress. 12:110-113 |
ISSN: | 1547-5921 0278-4491 |
DOI: | 10.1002/ep.670120207 |
Popis: | Nitric oxide and sulfur dioxide can be removed from flue gas by scrubbing with a lime slurry containing ferrous EDTA. Tests in a 0.90m diameter column with several commercial packings gave 99 to 99.9 percent SO2 removal and 10 to 60 percent NO removal. The absorption of NO is controlled by the liquid-film resistance, and the number of transfer units varies with the square root of the ferrous EDTA concentration, the 0.4 to 0.6 power of the liquid rate, and the − 1.0 power of the gas velocity, in agreement with predictions. The height of a transfer unit for NO absorption, corrected for end effects, was 10 to 15m, about 30 times the estimated values for SO2 absorption, which is gas-film controlled. The spray tower gave lower removal rates for both gases, but the ratio of transfer units was about the same as for the packed columns. |
Databáze: | OpenAIRE |