In situ U g-value measurement on three different glazing types

Autor: F Paschke, N Bishara, I Schulz, C Kocer, J Schneider, A Maier
Rok vydání: 2021
Předmět:
Zdroj: Journal of Physics: Conference Series. 2069:012134
ISSN: 1742-6596
1742-6588
Popis: This study presents in situ monitoring data of three different glazing systems over a period of one year. An insulated glass unit (IGU), a Vacuum Insulated Glass hybrid unit (VIG-hybrid) and an opaque architectural insulation module (AIM) were monitored under the equivalent environmental condition in this study. Different issues were observed and analyzed. It was found that the Ug-value cited by the manufacturers agrees with the Ug-values derived from the measured data, to within less than 5 % for the IGU and the VIG-hybrid. The consistency of the Ug-value of each glazing types one year after the start of monitoring was validated for similar environmental conditions. Depending on the magnitude of the resistance to heat flow, an increasing Ug-value was observed for a higher temperature difference between the inside and outside environments. The effect is much more significant for the glazing type with the largest Ug-value (IGU) and less significant for the glazing types with a high thermal resistance (VIG-hybrid, AIM).
Databáze: OpenAIRE