Long-term clinical course and prognostic factors of heart failure with reduced ejection fraction (HFrEF) patients underwent primary prophylactic implantable cardioverter defibrillator (ICD)
Autor: | M Sugawara, Y Kondo, Y Yoshino, S Ryuzaki, T Chiba, M Kitagawa, R Ito, M I Nakano, T Kajiyama, M A Nakano, Y Kobayashi |
---|---|
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | European Heart Journal. 43 |
ISSN: | 1522-9645 0195-668X |
DOI: | 10.1093/eurheartj/ehac544.380 |
Popis: | Background For decades, ICD is a well-established therapy for improving prognosis of structural heart disease with severe cardiac dysfunction, and ICD for primary prophylaxis against sudden cardiac death were routinely provided. However, long-term prognosis and clinical course are different in each individual patient with an ICD, and it is moreover unclear what kind of factors might have influences on their clinical outcomes. Purpose The aim of this study is to clarify long-term prognosis and predictors of future major adverse cardiac events (MACEs) in HFrEF patients with an ICD as primary prophylaxis in Japanese population. Methods We retrospectively analyzed our ICD database. Patients underwent primary prophylactic ICD implantation from 2006 to 2020 at our institute and met the criteria of ICD recommendation of the latest Japanese guideline. Its requirements are receiving optimal medication therapy, symptomatic heart failure (New York Heart Association classification II or greater), and severe cardiac dysfunction (left ventricular ejection fraction (LVEF) is 35% or less). Additionally, prior NSVT is considered Class I ICD recommendation. In the case of ischemic cardiomyopathy (ICM), ICD implantation was done at least 40 days after myocardial infarction and at least 90 days after revascularization. MACEs were defined as composite outcome of cardiovascular death, heart failure hospitalization, and appropriate ICD therapies. Results A total of 148 consecutive patients were enrolled (male, 120 (81%); age, 62.1±11.8 years; LVEF, 23.0±5.86%; left ventricular end-diastolic diameter (LVDd), 67.6±9.26mm; paroxysmal or persistent atrial fibrillation (AF), 38 (26%); NSVT, 113 (76%); use of class III antiarrhythmic drugs, 48 (32%); ICM, 49 (33%); cardiac resynchronization therapy (CRT), 63 (43%)). One hundred twenty patients (81%) were programmed with a shock-only zone over 200 beats per minute. The median follow-up duration was 58.5 months. Among those 148 patients, MACEs were occurred to 60 patients (41%). As a result of dividing all patients into two groups by the occurrence of MACE, LVEF and LVDd were worse in MACE(+) group, whereas, MACE(−) had greater number of co morbidities. The results of cox-regression analysis showed LVDd (HR: 1.07, 95% CI: 1.03–1.12, p Conclusions The incidence of MACEs in patients with an ICD and severe HFrEF was substantially high in this Japanese population. Etiology of ICM, left ventricle size, and AF were the potential risk factors for future MACEs. Funding Acknowledgement Type of funding sources: None. |
Databáze: | OpenAIRE |
Externí odkaz: |