Partial CT for in situ bridge NDE with 950 keV/3.95 MeV X-band linac source
Autor: | Takesi Fujiwara, Joichi Kusano, Hideyuki Sunaga, Wenjing Wu, Katsuhiro Dobashi, Mitsuru Uesaka, Eiji Tanabe, Naoki Nakamura, Haitao Zhu, Yoshie Otake, Ming Jin |
---|---|
Rok vydání: | 2014 |
Předmět: |
In situ
Materials science business.industry Mechanical Engineering X band Stiffness 3d model Collimator Condensed Matter Physics Linear particle accelerator Electronic Optical and Magnetic Materials law.invention Optics Mechanics of Materials law medicine Electrical and Electronic Engineering medicine.symptom business Projection (set theory) Noise (radio) |
Zdroj: | International Journal of Applied Electromagnetics and Mechanics. 45:301-306 |
ISSN: | 1875-8800 1383-5416 |
DOI: | 10.3233/jae-141844 |
Popis: | Computed tomography system for in situ NDE of degradation bridges is under development, with portable 950 keV/3.95 MeV X-band linac as x-ray source. Collimator is adopted to reduce scattered X-ray noise and 3D model can be built from sectional images so that it becomes possible to evaluate mechanical characters of bridges referring to structural analysis with reduced stiffness. Furthermore, considering limitation of projection angle range during in situ scanning, recon- struction technique with incomplete projection data is studied with experimental data. |
Databáze: | OpenAIRE |
Externí odkaz: |