Unjailing of the septal perforator using a rotational atherectomy device prior to alcohol septal ablation in a patient with symptomatic hypertrophic obstructive cardiomyopathy
Autor: | William W. O'Neill, Adam Greenbaum, Mir B Basir |
---|---|
Rok vydání: | 2014 |
Předmět: |
Alcohol septal ablation
medicine.medical_specialty medicine.diagnostic_test business.industry medicine.medical_treatment Cardiomyopathy General Medicine Ablation medicine.disease Obstructive cardiomyopathy Atherectomy Internal medicine Coronary stent Angiography medicine Cardiology Radiology Nuclear Medicine and imaging cardiovascular diseases Radiology Cardiology and Cardiovascular Medicine business Rotational atherectomy device |
Zdroj: | Catheterization and Cardiovascular Interventions. 84:E26-E29 |
ISSN: | 1522-1946 |
DOI: | 10.1002/ccd.25511 |
Popis: | We report a novel approach in which successful unjailing of the septal perforator was performed through the side branch of a coronary stent using a rotational atherectomy device for the purpose of alcohol septal ablation in a patient with symptomatic hypertrophic obstructive cardiomyopathy. © 2014 Wiley Periodicals, Inc. |
Databáze: | OpenAIRE |
Externí odkaz: |