Applicability of the MCNPX particle transport code for determination of the source correction effect in positron lifetime measurements on thin polymer films
Autor: | Alan W. Hunt, J. M. Urban-Klaehn, E. S. Peterson, R. Spaulding |
---|---|
Rok vydání: | 2007 |
Předmět: | |
Zdroj: | physica status solidi c. 4:3731-3734 |
ISSN: | 1610-1642 1862-6351 |
DOI: | 10.1002/pssc.200675819 |
Popis: | The method presented herein uses the MCNPX Monte Carlo particle transport code to track individual positrons and other particles through geometry that accounts for the detectors, backing foils, samples and sources with their actual sizes, positions and material characteristics. Polymer material, polydimethylsiloxane (PDMS), with different thickness of films served as samples. The excellent agreement between the experimental results and the MCNPX simulation of source correction effects for varied positron sources and different film thicknesses validates the applicability of the MCNPX code. |
Databáze: | OpenAIRE |
Externí odkaz: |