Substantial radiation dose reduction with consistent image quality using a novel low-dose stone composition protocol
Autor: | Paul Apfaltrer, Christian Seitz, Thomas H. Helbich, Christian Schestak, Julian Veser, Mehmet Özsoy, Helmut Ringl, Anja Dutschke, Elisabeth Petter, Georg Apfaltrer, Pascal A. T. Baltzer |
---|---|
Rok vydání: | 2020 |
Předmět: |
business.industry
Image quality Urology Urinary system Radiation dose Low dose 030232 urology & nephrology Effective dose (radiation) 03 medical and health sciences chemistry.chemical_compound 0302 clinical medicine chemistry 030220 oncology & carcinogenesis Uric acid Medicine Dose reduction Stone composition Nuclear medicine business |
Zdroj: | World Journal of Urology. 38:2971-2979 |
ISSN: | 1433-8726 0724-4983 |
Popis: | To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p |
Databáze: | OpenAIRE |
Externí odkaz: |