Erythrocyte indices business.industry Anemia General Medicine Iron deficiency 030204 cardiovascular system & hematology medicine.disease Gastroenterology 03 medical and health sciences 0302 clinical medicine Internal medicine medicine ANEMIA IRON DEFICIENCY business Mass screening 030215 immunology |
Zdroj: | Orvosi Hetilap. 157:35-38 |
ISSN: | 1788-6120 0030-6002 |
Popis: | Introduction: Screening for iron deficiency, which affects a significant proportion of the population, is a burning issue in the health care system. Aim: The aim of the authors was to examine whether low mean cell hemoglobin concentration measured by automated hematology analyzers is a suitable screening parameter for iron deficiency. Method: The data for this study included a total of 247,705 complete blood counts and 10,840 tests with different parameters of iron metabolism. Patients were evaluated at Somogy County Kaposi Mór Teaching Hospital during a period of 30 months between January 1, 2013 and June 30, 2015. Low cell hemoglobin values were analyzed with iron metabolism parameters measured simultaneously. Results: A total of 830 patients whose iron metabolism parameters were measured simultaneously had low mean cell hemoglobin ( |