Analysis of the flow imbalance in the KSTAR PF cryo-circuit
Autor: | Nam-Won Kim, K.M. Moon, Hyunjung Lee, Young-Joo Lee, Jae-Jun Joo, D.S. Park, Young Min Park, H.L. Yang, S.W. Kwag |
---|---|
Rok vydání: | 2015 |
Předmět: |
Pressure drop
Materials science Mass flow meter Electromagnet Mechanical Engineering Superconducting magnet Mechanics Helium-3 refrigerator law.invention Physics::Fluid Dynamics Nuclear magnetic resonance Nuclear Energy and Engineering law Magnet KSTAR General Materials Science Body orifice Civil and Structural Engineering |
Zdroj: | Fusion Engineering and Design. 101:199-203 |
ISSN: | 0920-3796 |
DOI: | 10.1016/j.fusengdes.2015.07.022 |
Popis: | The KSTAR PF cryo-circuit is a quasi-closed circulation system in which more than 370 g/s of supercritical helium (SHe) is circulated using a SHe circulator. The heated helium from superconducting magnet is cooled through sub cooler (4.3 K). The circulator is operated at 4.5 K and 6.5 bar, and the pressure drop of the circuit is kept at 2 bar in order to maintain the supercritical state and circulator stability. The circuit is connected with helium refrigerator system, distribution system, and supercritical magnet system. It has a hundred branches to supply supercritical helium to the poloidal field superconducting magnet. The branch was designed to optimize the operation conditions and they are grouped for one cryogenic valve has the same length within the cardinal principle of the optimization. Five cryogenic valves are installed to control the mass flow rate, and seven orifice mass flow meters, differential pressure gauges and temperature sensors were installed in front of the magnet in the distribution because upper magnet and lower magnet is symmetric theoretically. The cryogenic pipe line was manufactured with elevation about 10 m between upper magnet and lower magnet. The inlet and outlet helium feed-through were installed at the coil inside in case of KSTAR PF1–PF5 upper magnet and lower magnet. The flow imbalance is caused by void fraction and it could be changed due to manufacturing process even if it has the same length of cooling channel. This creates an imbalance among cooling channels and temperatures are slightly different. The flow was reduced and detoured due to the pressure rise rapidly at inlet and outlet during magnet operation. Therefore, the orifice mass flow meters are installed in front of the PF1–PF5 upper magnet and lower magnet in order to investigate flow trend and the thermos-hydraulic behavior is analyzed during PF magnet operation. |
Databáze: | OpenAIRE |
Externí odkaz: |