Autor: |
Muhamad Ryanto, Bakhtiar Abu Bakar, Ketut Abimanyu Munastha, Ahmad Munandar, Chandra Afriade Siregar, R. Didin Kusdian |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
2020 14th International Conference on Telecommunication Systems, Services, and Applications (TSSA. |
DOI: |
10.1109/tssa51342.2020.9310902 |
Popis: |
The purpose of this paper is to determine the vibration problem in Jeranjang Electric Steam Power Plant Structure at Lombok, due to Pedestal Turbine vibration by using an accelerometer sensor as an instrumentation tool and three frequency analysis method, Ibrahim Time Domain (ITD), Stochastic Subspace Identification (SSI), Eigensystem Realization Algorithm (ERA). There are three positions of the measurement: Top Turbine Foundation (TTF), Bottom Turbine Foundation (BTF), and Top Turbine House (TTH). The result indicated that one of the TTH sensors near the generator exceeds a velocity limit that makes an excessive vibration felt inside the powerplant building. |