Late Results of Replacement of Cardiac Valves by Dura-Mater Allografts
Autor: | Zerbini Ej, Luiz Boro Puig, Noedir Antônio Groppo Stolf |
---|---|
Rok vydání: | 1980 |
Předmět: |
medicine.medical_specialty
business.industry Dura mater Incidence (epidemiology) 030232 urology & nephrology Biomedical Engineering Medicine (miscellaneous) Fungal endocarditis Bioengineering General Medicine 030204 cardiovascular system & hematology medicine.disease Late results Surgery Biomaterials 03 medical and health sciences 0302 clinical medicine medicine.anatomical_structure Aortic valve replacement Bacterial endocarditis Mitral valve Cardiac valve medicine business |
Zdroj: | The International Journal of Artificial Organs. 3:104-107 |
ISSN: | 1724-6040 0391-3988 |
DOI: | 10.1177/039139888000300211 |
Popis: | Homologous dura-mater valve was employed in a series of 2.338 patients in the period between January 1971 and January 1979. A restricted group of the first 272 patients were followed-up from six to eight years. This study showed gratifying results following mitral and tricuspid valves replacement and not as satisfactory results after aortic replacement. The postoperative complications were, for mitral valve: fungal endocarditis (0.68%), bacterial endocarditis (2.56%) thromboembolism (1.36%) valve dysfunction (12.9%) and reoperation was performed in 5.12% of the cases. For aortic valve replacement there was fungal endocarditis in 1.36% of cases, bacterial endocarditis in 5.68%, valve dysfunction in 29.54% and the incidence of reoperation was 23.28%. No anticoagulants were employed in this series. |
Databáze: | OpenAIRE |