Switching characteristics of a gas trigatron operated in single and double trigger mode

Autor: K. Nanu, V.K. Rohatgi, S. T. Iyengar, P. H. Ron
Rok vydání: 1990
Předmět:
Zdroj: IEEE Transactions on Electrical Insulation. 25:381-392
ISSN: 0018-9367
DOI: 10.1109/14.52388
Popis: The delay time, risetime, jitter, and operating range have been studied in detail for single- as well as double-trigger mode. The best switching performance is obtained in a double-trigger mode for a trigger polarity configuration that produces high field intensification between the opposed trigger electrodes. For a trigatron with a gap spacing of 9.7 mm, using air at atmospheric pressure, an operating range of 12 to 28 kV with low delay time ( >
Databáze: OpenAIRE