K-shell aluminum resonance line ratios for plasma diagnosis using spot spectroscopy

Autor: D. Duston, J. C. Davis, John P. Apruzese
Rok vydání: 1986
Předmět:
Zdroj: Journal of Quantitative Spectroscopy and Radiative Transfer. 36:339-344
ISSN: 0022-4073
DOI: 10.1016/0022-4073(86)90057-9
Popis: Using a detailed atomic model of K shell aluminum ions, we have calculated four diagnostic resonance line ratios as a function of temperature and density for cylindrical aluminum plasmas of diameter 50 and 100 μm, assumed in collisional-radiative equilibrium. The ion densities vary from 10 19 cm -3 to 10 21 cm -3 , the temperatures range from 200 to 700 eV. The conditions are applicable to experiments using the spot spectroscopy technique for plasma diagnosis.
Databáze: OpenAIRE