Autor: V. N. Kirichenko, A. V. Tataurov, A. K. Budyka
Rok vydání: 2002
Předmět:
Zdroj: Theoretical Foundations of Chemical Engineering. 36:264-267
ISSN: 0040-5795
DOI: 10.1023/a:1015899921547
Popis: The theory of aerosol filtration is used to demonstrate the feasibility of reducing the dimensions and flow resistance of high-performance fibrous aerosol filters, and the lower limits of these values are determined. Increasing the filter packing density by a factor of 3 to 4 and reducing the scale of spatial configuring of the bed by a factor of 5 to 6 will reduce the filter volume by a factor of 2 to 3 and the filter resistance by more than one order of magnitude, without affecting the capturing performance of the filter with respect to the most easily penetrating particles.
Databáze: OpenAIRE