Effect of set-up heights on the performance of pot-in-pot cooling system for storing food and drugs at ambient temperature
Autor: | Kamaldeen O Abdulrahman, S. A. Yahaya, Kareem A Akande, Ibrahim I Enagi, Aisha Olaitan Raji |
---|---|
Rok vydání: | 2019 |
Předmět: | |
Zdroj: | FUOYE Journal of Engineering and Technology. 4 |
ISSN: | 2579-0625 2579-0617 |
Popis: | The research aimed at evaluating the effect of set-up height on the performance of earthenware pot-in-pot cooling system. The pots were set up at different heights; H1 (0 m), H2 (0.5 m) and H3 (1 m) and observed for 59 days from 8:00am to 6:00pm daily. The inner temperatures obtained from the three different arrangements were determined using standard methods. The result showed that increasing the height from ground level (0 m) to 1 m increases the mean cooling effect by 8 %. Generally, it was observed that only the set-up height at 1 m proved to have maximum efficiency of the pot-in-pot system performance. Keywords— Cooler, Efficiency, Evaporative cooling, Set-up height, Pot-in-pot, Preservation |
Databáze: | OpenAIRE |
Externí odkaz: |