Autor: |
Paul R. Weckler, Nachiket Kotwaliwale, Gerald H. Brusewitz |
Rok vydání: |
2006 |
Předmět: |
|
Zdroj: |
Biosystems Engineering. 94:199-206 |
ISSN: |
1537-5110 |
Popis: |
Digital X-ray imaging has very good potential for non-destructive quality evaluation of intact pecans. Information extracted from X-ray images requires knowledge of the X-ray attenuation properties of the individual components of pecans, viz . nutmeat and shell. Linear attenuation coefficients of pecan components were determined from digital X-ray images taken under polychromatic X-ray beam. Attenuation coefficient varied with X-ray tube peak voltage and sample thickness. Regression models with a value for the coefficient of determination R 2 of more than 0·9 were developed to predict attenuation coefficient of pecan nutmeat at a given voltage and nutmeat thickness. The linear attenuation coefficient of pecan shell was higher than that of nutmeat. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|