Equivalent Enthalpy Drop Method with Application in a 330 Mw Double Pumping Cogeneration Unit and its Thermal Characteristics Analysis

Autor: Qian Jun Li, Yong Xin Fang, Yu Zhu, Li Kun Zheng
Rok vydání: 2013
Předmět:
Zdroj: Applied Mechanics and Materials. :802-809
ISSN: 1662-7482
DOI: 10.4028/www.scientific.net/amm.446-447.802
Popis: It is quite convenient and flexible to adopt the equivalent enthalpy drop method, in order to analyze a thermal system. In this report, a 330MW cogeneration unit will be chosen, as a case in point, to provide quantitative calculation and qualitative analysis in both global and local aspects. According to our research, this cogeneration unit is designed to operate in a double pumping status. It has such properties as follows: Under 85%BMCR double pumping condition, its highest efficiency of power generation is obtained. In pure condensing conditions with around 70% load, the steam consumption rate reaches minimal level. The reason for this phenomenon lies in the maximal net equivalent enthalpy drop of new steam, although with 70% load, the power generation efficiency is much lower than that in rated pure condensing conditions.