Autor: |
Zhu Jun Tian, Fu Quan Jia |
Rok vydání: |
2014 |
Předmět: |
|
Zdroj: |
Applied Mechanics and Materials. :2445-2448 |
ISSN: |
1662-7482 |
Popis: |
NIPGA technology is used in order to detect the total nitrogen content in sewage quickly. D-D neutron generator is used as the neutron source and BGO detector is used to detect gamma rays of nitrogen. The simulated result of MCNP shows the nitrogen’s limit of detection is 0.2 mg/L and the total nitrogen in V-type water can be detected. So this method can be used to detect the total nitrogen content in sewage quickly. |
Databáze: |
OpenAIRE |