In Vivo Spectroscopy and Imaging of the Ovary In Vivo at 3 Tesla and Spectroscopy on Biopsy at 8.5 Tesla

Autor: Sinead Doran, Peter Russell, Rebecca Chin, Carolyn E. Mountford, Peter Stanwell, Allan Ferrier, James Christie, Roger Bourne
Rok vydání: 2005
Předmět:
Zdroj: Journal of Women's Imaging. 7:71-76
ISSN: 1084-824X
DOI: 10.1097/01.jwi.0000170626.02187.22
Popis: In vivo spectroscopy and imaging of the ovary at 3T can provide diagnostic information preoperatively on patients with ovarian masses. Here is the first report of a case where the in vivo MRI and MRS at 3T were undertaken on a patient with an ovarian mass distinguishing the malignant from the cystic component. Spectroscopy on biopsies obtained intraoperatively and recorded at 8.5T provided a diagnosis of poorly differentiated malignant tumor. The MR studies were undertaken blind and the diagnosis subsequently confirmed histologically.