020209 energy Nuclear engineering 02 engineering and technology Point kinetics Condensed Matter Physics Turbine Test (assessment) Power (physics) 020303 mechanical engineering & transports 0203 mechanical engineering Nuclear Energy and Engineering Turbomachinery 0202 electrical engineering electronic engineering information engineering Benchmark (computing) Environmental science Transient (oscillation) Test data |
Zdroj: | Nuclear Technology. 61:238-252 |
ISSN: | 1943-7471 0029-5450 |
Popis: | During the Arkansas Nuclear One Unit 2 (ANO-2) initial power ascension, four system transient tests were conducted. The four tests were: turbine trip from 98.2% power; total loss of flow from 81% power; a full-length control element assembly (CEA) drop from 49.4% power; and a part length CEA drop from 49.2% power. Middle South Services has undertaken a project to benchmark RETRAN-02 against these ANO-2 startup tests. The primary purpose of this project is to develop validated RETRAN-02 models of ANO-2, which give a good prediction of the measured data. The RETRAN model used is a two-loop representation of ANO-2, with a point kinetics representation of the core. For the turbine trip test, the comparison of RETRAN-02/MOD001 predictions against test data indicates that RETRAN-02 properly predicts the significant test events and agrees well with test data. |