950keV, 3.95MeV and 6MeV X-band linacs for nondestructive evaluation and medicine

Autor: Shigeki Fukuda, Katsuhiro Dobashi, Kazuyuki Demachi, Joichi Kusano, Eiji Tanabe, Takeshi Fujiwara, Shuji Matsumoto, Mitsuru Uesaka, Naoki Nakamura, Toshiyasu Higo, Mitsuhiro Yoshida, Takuya Natsui, Haito Zhu, Masashi Yamamoto, K. P. Lee, Tomohiko Yamamoto
Rok vydání: 2011
Předmět:
Zdroj: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 657:82-87
ISSN: 0168-9002
DOI: 10.1016/j.nima.2011.07.026
Popis: We are developing compact X-band linac X-ray sources for nondestructive evaluation and medicine. First, we develop a portable X-ray system by a 950 keV 9.4 GHz X-band linac to realize on-site inspection. We use a low power (250 kW) magnetron as an RF source for compactness of the whole system. Since the RF power source is quite small and the stored energy in the structure is also small, we faced the problem of beam loading and current/RF-power oscillation. We are analyzing the problem by the circuit model. We plan to use this system for erosion inspection of metal pipes of petrochemical complex. By adopting a side-coupling cavity design to avoid the oscillation, we have developed 6 MeV X-band (9.3 GHz) linac for pinpoint dynamic tracking cancer therapy. Furthermore, we are manufacturing 3.95 MeV X-band (9.3 GHz) linac X-ray source with flexible waveguides for on-site bridge inspection. Updated results and situations are presented.
Databáze: OpenAIRE