Over 5-Year Follow-up of Total Knee Replacement with the Okayama University Type(Mark II)
Autor: | Kohei Ise, Kenichi Yamashiro, Hideki Sonoda, K. Hirota, Eiji Kawaguchi, Kiminori Sakamoto, Tetuya Hirano, Kunihiko Tomoda, Haruaki Takeuchi, Koji Akasaki |
---|---|
Rok vydání: | 1991 |
Předmět: | |
Zdroj: | Orthopedics & Traumatology. 40:55-58 |
ISSN: | 1349-4333 0037-1033 |
DOI: | 10.5035/nishiseisai.40.55 |
Popis: | We have operated on patients complaining of severe knee joint dysfunction (52 joints) from osteo-arthritic changes using Okayama University type (Mark II) or over 5 years. And Post-operative knee function is evaluated clinically and roentgenologically in 12 patients (13 joints). Results are as follows: femoro-tibial angle (170°-177°), medial tibial angle (85°-90°), posterior tibial angle (82°-90°), and clinical evalution is good.In spite of clinically good function, sinking of the tibial component is shown roentgenologically in only one patient (1 joint). |