The half-life of 192Ir

Autor: S.E.M. Lucas, D.F.G. Reher, M.J. Woods, G. Sibbens
Rok vydání: 1992
Předmět:
Zdroj: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:346-348
ISSN: 0168-9002
DOI: 10.1016/0168-9002(92)90179-8
Popis: The current interest in the use of 192 Ir for brachytherapy prompted a re-evaluation of existing half-life values. Using the evaluation criteria adopted in a recent IAEA-Coordinated Research Programme, it was determined that the uncertainty in the half-life obtained by evaluating published data spanning the last 20 years is too large. Further measurements of the half-life have been carried out using high-pressure re-entrant ionization chambers. The results of these latest measurements are presented together with a re-evaluation of the half-life using the IAEA-CRP criteria. The recommended half-life of 192 Ir is 73.830 ± 0.018 d.
Databáze: OpenAIRE