Long-Base Free Electron Laser Resonant Cavity
Autor: | S.C. Bender, Q. D. Appert, A. C. Saxman, Eric L. Miller, T. Swann |
---|---|
Rok vydání: | 1985 |
Předmět: | |
Zdroj: | SPIE Proceedings. |
ISSN: | 0277-786X |
DOI: | 10.1117/12.976119 |
Popis: | A 65-meter resonant cavity has been constructed in order to experimentally determine the characteristics of long resonant cavities as would be required for a free electron laser1 (FEL). A version using normal incidence mirrors is reported here, and another that includes a grazing incidence mirror is forthcoming. Either version is designed to simulate a FEL operating at 0.5 micron wavelength and is near-concentric with a stability parameter of 0.98. Argon-ion plasma tubes simulate the laser gain that would be provided by a wiggler in an actual FEL. The cavity was constructed on a seismic slab and air turbulence effects were reduced by surrounding the beam with helium in 6" diameter tubes. AlignTept sensitivities are reported and compared to geometrical and diffraction predic-tions3' with good agreement. |
Databáze: | OpenAIRE |