Trueness verification survey for blood lead concentration measurement in Chinese clinical laboratories
Autor: | Wei Wang, Kun Zhong, Jianping Li, Zhi G. Wang, Mingxia Liu, Fa L. He, Junwei Xin, Shuai Yuan |
---|---|
Rok vydání: | 2017 |
Předmět: |
medicine.medical_specialty
Traceability General Chemical Engineering 010401 analytical chemistry Clinical settings General Chemistry 01 natural sciences 0104 chemical sciences Lead measurement 03 medical and health sciences Reporting rate 0302 clinical medicine Certified reference materials External quality assessment medicine Medical physics 030212 general & internal medicine Overall performance Safety Risk Reliability and Quality Lead (electronics) Instrumentation Mathematics |
Zdroj: | Accreditation and Quality Assurance. 23:97-102 |
ISSN: | 1432-0517 0949-1775 |
DOI: | 10.1007/s00769-017-1304-6 |
Popis: | The results of trueness verification for blood lead measurement were analyzed in a 2016 nationwide external quality assessment (EQA) survey, in order to evaluate current approaches of blood lead measurement in Chinese Laboratories and their traceability to certified reference materials (CRMs). A panel of 2 frozen whole blood CRMs with values assigned by an absolute quantitative method was provided to 12 laboratories with satisfactory performances from the 2015 blood lead EQA scheme. Participants were required to measure the samples 5 times each day for 3 consecutive days and report all 15 data, which were then calculated for means and standard deviations. Data were statistically analyzed by adopted method groups, before comparing with the assigned values to assess the trueness of blood lead measurement using different approaches. Eleven laboratories reported on schedule, rendering a reporting rate of 91.7 %. The target values for the two batches were (37.6 ± 2.7) μg/L and (124.6 ± 4.5) μg/L, respectively. By the evaluation criterion of target value ± 20 µg/L, the pass rates were 72.7 % for the lower concentration and 54.5 % for the higher concentration, while 5 out of 11 laboratories delivered satisfactory results for both CRMs. The overall performance of the few participating laboratories in this EQA survey was basically acceptable by CLSI standard on the whole, yet barely desirable for the higher concentration. Therefore, trueness verification of blood lead measurement with CRMs is potentially necessary for national EQA schemes, which can be imperative as part of the validation procedures of analytical methods in clinical settings. |
Databáze: | OpenAIRE |
Externí odkaz: |