HPLC/EC Assay of the Distribution of the Antimalarial Arteether Into Fat and Muscle Tissue Following Intravenous Administration

Autor: Y. L. Zeng, John K. Baker, H. T. Chi
Rok vydání: 1994
Předmět:
Zdroj: Journal of Liquid Chromatography. 17:1365-1373
ISSN: 0148-3919
DOI: 10.1080/10826079408013769
Popis: An HPLC/electro-chemical method with an internal standard was developed for the analysis of arteether in fat and muscle tissue giving good recovery and accuracy with moderate precision. Following an intravenous administration of arteether (11.6 mg/Kg in a micro-emulsion), it was found that after 15 minutes the arteether concentration was 18.4 ± 13.1 μg/g (15.8% of administered dose) in fat and 1.35 ± 0.25 μg/g (5.8% of dose) was found in muscle tissue. The concentration of arteether in fat tissue initially dropped very rapidly (t1/2 = 14 min), followed by a much slower rate of elimination (t1/2 = 34 hr). Using the same dose, vehicle, and route of administration, arteether had been reported to be cleared from plasma at a higher rate (t1/2 = 10 min).
Databáze: OpenAIRE