Autor: |
Hassan Al Kanti, Otman El Hajjaji, Tarek El Bardouni, Maged Mohammed |
Rok vydání: |
2022 |
Zdroj: |
Polish Journal of Medical Physics and Engineering. 28:52-59 |
ISSN: |
1898-0309 |
Popis: |
Introduction: This work aims to calculate the ambient and personal dose equivalent conversion coefficients. Material and methods: The conversion coefficients have been calculated using MC simulation. Additionally, this paper proposes a new method that depends on an analytical approach. Results: The obtained results in good agreement between MC and an analytical approach were observed. The obtained results were compared to those published in ICRU 57 report. Conclusions: We deduced that the analytical approach is as effective and suitable as the MC simulation to calculate the operational quantity conversion coefficients. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|