Autor: |
Kisung Lee, Saewoong Bahk, B. Hong, J. Y. Kim, S.W. Seo, V.A. Gapienko, S. H. Ahn, Ye-Seul Kim, Sangkyu Park, S.J. Lee, R. Amirikas, K.M Baik, Soon-Kwon Nam, D.G. Koo, Seong Jong Hong, K. S. Sim, J.T. Rhee, M. Y. Pac, I. T. Lim, Y. J. Kim |
Rok vydání: |
2001 |
Předmět: |
|
Zdroj: |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 465:447-454 |
ISSN: |
0168-9002 |
Popis: |
This paper presents the results from cosmic ray tests performed in the framework of R&D effort on the forward Resistive Plate Chamber (RPC) for CMS. A double gapRPC of dimensions 50 � 50 cm 2 with 2 mm gas gaps was tested. We report data on the use of tetrafluorethane-based gas mixture, with additions of water vapour and SF6. Efficiency, time resolution and cross-talk behaviour of the detector were investigated. # 2001 Elsevier Science B.V. All rights reserved. PACS: 29.40.Cs |