Shear capacity estimation of core steel tube reinforced PCCC column-beam interior joint under quasi-static load

Autor: Yuan Fang, Feng Yu, Chaochao Feng, Xing Chen, Siyong Tan
Rok vydání: 2023
Předmět:
Zdroj: Advances in Structural Engineering. :136943322311742
ISSN: 2048-4011
1369-4332
DOI: 10.1177/13694332231174253
Popis: In this study, the quasi-static tests were conducted on 13 core steel tube (CST) reinforced PVC-CFRP confined concrete (PCCC) column-beam interior joints. Distinct shear failure occurred in all joint specimens. The load-displacement hysteresis curves appeared pinching phenomenon, and the shape of hysteresis loops gradually deformed from shuttle to arch and finally changed to reverse S shape. The overall shape of hysteresis curves were relatively full, demonstrating that the joints had favorable seismic performances and energy dissipation capacity. The strain development law of materials in the joint area in the process of stress was clarified. The increment of joint stirrup ratio ([Formula: see text]), axial compression ratio ([Formula: see text]), column reinforcement ratio ([Formula: see text]) or beam reinforcement ratio ([Formula: see text]) improved the calculated shear capacity of the joints. The calculated shear capacity increased first and then decreased slightly as the diameter-thickness ratio of CST ([Formula: see text]) increased. In comparison, spacing of CFRP strip had little impact on the calculated shear capacity. Additionally, the concrete strength enhancement coefficient ([Formula: see text]) and joint stirrup utilization coefficient ([Formula: see text]) were introduced respectively to modify the shear capacity of concrete and joint stirrups, and a simplified formula for predicting the shear capacity of CST reinforced PCCC column-beam interior joints under quasi-static load was proposed. The predicted results agreed well with the test data.
Databáze: OpenAIRE