Enhancement of Voltammetric Signals Using a Graphene Oxide Modified Carbon Electrode for Electrochemical Paper-Based Analytical Devices
Autor: | Phoonthawee Saetear, Thitaree Pimklang, Akhmad Sabarudin, Duangjai Nacapricha, Kitima Sirivibulkovit, Pasit Pakawatpanurat |
---|---|
Rok vydání: | 2019 |
Předmět: |
Materials science
Graphene Mechanical Engineering Oxide 02 engineering and technology Paper based 010402 general chemistry 021001 nanoscience & nanotechnology Electrochemistry 01 natural sciences 0104 chemical sciences law.invention chemistry.chemical_compound Modified carbon Chemical engineering chemistry Mechanics of Materials law Electrode General Materials Science 0210 nano-technology Voltammetry |
Zdroj: | Key Engineering Materials. 824:197-203 |
ISSN: | 1662-9795 |
DOI: | 10.4028/www.scientific.net/kem.824.197 |
Popis: | This work presents an enhancement of the voltammetric signal on an electrochemical paper-based analytical device (ePAD) using a graphene oxide (GO) modified carbon electrode. The ePAD is fabricated using a screen printing technique for fabrication of the hydrophobic area and three electrode strips. The graphene film was directly prepared on ePAD by dropping 2 µL of GO dispersed in water onto the working electrode surface and leaving it to dry at room temperature. The electrochemical reduction process of GO was carried out by applying a constant voltage of -1.20 V (vs. Ag/AgCl electrode strip) in 0.1 M KCl for 800 s. The GO-modified carbon working electrode on ePAD was readily obtained and ready to use after removing KCl solution. We tested the enhancement of the voltammetric signal on ePAD with a 6 mM [Fe(CN)6]4–/3– redox couple in 0.1 M KCl supporting electrolyte solution. Our results obtained from cyclic voltammograms showed that the unmodified working electrode and the GO-modified working electrode on ePAD provided similar anodic and cathodic peaks. Due to accelerated electron transfer process, it was found that the GO-modified working electrode on ePAD provided approximately a 2-fold increase in voltammetric signals when compared to the unmodified working electrode on ePAD. The reproducibility (inter-day precision) of the voltammetric signal measurement using a GO-modified working electrode on ePAD was acceptable. The relative standard deviation (RSD) was 5-8%. Therefore, the GO-modified carbon working electrode on ePAD offers an effective approach to enhance the signal and sensitivity for chemical analysis. |
Databáze: | OpenAIRE |
Externí odkaz: |