Accurate ultrasonic range measurement using MLS-modulated continuous waves

Autor: Z.G. Huang, C.J. Qiao, Y.K. Wang
Rok vydání: 2015
Předmět:
Zdroj: Measurement. 60:178-185
ISSN: 0263-2241
DOI: 10.1016/j.measurement.2014.10.017
Popis: Ultrasonic range measurement has the potential to obtain higher accuracy results while using continuous-wave signals due to its favorable capability of noise resistance. But in short distance ranging applications especially in the space-limited fields, there usually exists strong multiple echoes which will decline the distance measurement accuracy seriously. This paper presents a method to solve this problem through utilizing MLS-modulated continuous-wave signals. Meanwhile, this paper applies a combination of the cross-correlation method and phase shift technique for the high-resolution ultrasonic distance measurement. The synergy above would lead to very popular results. For example, the uncertainty in the measured distance is less than 40 μm for distances up to 200 mm in distilled water.
Databáze: OpenAIRE