Removing gaseous contaminants in {sup 3}He by cryogenic stripping

Autor: M. Benapfl, P. Biltoft, A. Coombs
Rok vydání: 1995
Předmět:
DOI: 10.2172/179274
Popis: The Tritium Operations Group at LLNL, Tritium Facility has recently developed a {sup 3}He recovery system to remove argon, xenon, neon, hydrogen, and all other contaminants from the {sup 3}He stream in an Accelerator Production of Tritium (APT) experimental apparatus. In this paper the authors will describe in detail the background information, technical requirements, the design approach, and the results of their experimental tests. The authors believe this gas purification system may have other applications as it provides at a reasonable cost an efficient method for purification of gaseous helium.
Databáze: OpenAIRE