Abstract 4967: Label-free collection of prostate circulating tumor cells using microfluidic Vortex technology
Autor: | Melanie Triboulet, Dino Di Carlo, Elodie Sollier, Matthew Rettig, Melissa Matsumoto Di Carlo, Edward Pao, Rajan P. Kulkarni, Clementine A. Lemaire, Corinne Renier, Stefanie S. Jeffrey, Sandy Srivinas, James Che |
---|---|
Rok vydání: | 2016 |
Předmět: |
Oncology
Cancer Research medicine.medical_specialty Pathology Vimentin 02 engineering and technology 01 natural sciences Prostate cancer Circulating tumor cell Internal medicine LNCaP medicine biology business.industry 010401 analytical chemistry Cancer 021001 nanoscience & nanotechnology medicine.disease Primary tumor 0104 chemical sciences Prostate-specific antigen biology.protein Prostate Circulating Tumor Cells 0210 nano-technology business |
Zdroj: | Cancer Research. 76:4967-4967 |
ISSN: | 1538-7445 0008-5472 |
Popis: | BACKGROUND Prostate cancer is among the most common cancers in men worldwide. Better markers than Prostate Specific Antigen (PSA) are still needed for the detection and monitoring of disease progression. Circulating Tumor Cells (CTCs) are shed into the blood stream from primary tumor(s) and may play key roles in the metastatic process. Liquid biopsies have emerged as a promising approach, with a correlation between the CTC numbers and patient prognosis for prostate cancer. CTCs have also been shown to enable early detection of recurrence, and could be potential candidates for guiding cancer therapy in real-time [1]. Current CTC enrichment technologies, including immuno-affinity and size-based filtration methods, have focused on high capture efficiency with sometimes tedious sample preparation and overall low purity. METHOD Here, we describe the use of the microfluidic Vortex Chip [2] for rapid and size-based isolation of CTCs from the blood of 23 patients with advanced prostate cancer, and 10 healthy donors; 5 being RESULTS Preliminary work with LNCaP prostate cancer cells spiked in blood showed a 29% capture efficiency and 50% purity. In vitro cell assays confirmed that cells enriched with Vortex chip were alive and proliferating for up to 7 days. For 23 patient samples, CTCs were captured (0.5 - 20 CTCs/mL) with high purity (3.6 - 72.3%), in less than 1H, without prior sample preparation. 11.5% of the cells collected were CK and PSA-negative, but some were identified as undergoing epithelial-mesenchymal transition (EMT) following staining for vimentin and N-cadherin. Few atypical cells were also isolated from age-matched healthy donors (0.7 - 2.8 CTCs/mL), while none was detected in younger healthy donors. Using a threshold calculated from the age-matched healthy donors (3.31 CTCs/mL = mean + 2CV), 70% of the patients were characterized as “positive for CTCs”. No correlation was found between CTC counts and elevated PSA level. CONCLUSION These results demonstrate the ability to rapidly collect pure populations of CTCs in metastatic prostate cancer, independent of surface marker expression, without prior sample preparation. Future studies will use chips with optimized capture performance, sample recycling, and will include CTC molecular analysis by targeted panel sequencing. A larger cohort of healthy donors is also being examined to determine a statistically-robust CTC baseline for this size-based capture approach. [1] Scher Hi, et al., J. Clin. Oncol. 2015 [2] Sollier E, et al., Lab Chip 2014 Citation Format: Edward Pao, Corinne Renier, Clementine Lemaire, James Che, Melissa Matsumoto Di Carlo, Melanie Triboulet, Sandy Srivinas, Stefanie S. Jeffrey, Rajan P. Kulkarni, Matthew Rettig, Elodie Sollier, Dino Di Carlo. Label-free collection of prostate circulating tumor cells using microfluidic Vortex technology. [abstract]. In: Proceedings of the 107th Annual Meeting of the American Association for Cancer Research; 2016 Apr 16-20; New Orleans, LA. Philadelphia (PA): AACR; Cancer Res 2016;76(14 Suppl):Abstract nr 4967. |
Databáze: | OpenAIRE |
Externí odkaz: |