Autor: |
K. Kephart, F. Cogswell, R. Madrak, D. Allspach, Tony Liss, L. Nodulman, C. Rivetta, T. J. Phillips, Z. Y. Feng, A. Mukherjee, V. J. Guarino, J.D. Taylor, C. Neu, J. C. Yun, A. Holloway, T. Miao, Yongsun Kim, T. Affolder, R. Thurman-Keup, N. Dressnandt, R. Sandberg, Intae Yu, M. Binkley, R. Roser, W. Reigler, H. H. Williams, P. N. Singh, D. Ambrose, J. Bialek, R. Haggerty, J. Greenwood, R. A. Richards, N. Lockyer, L. Galtieri, K. T. Pitts, M. Newcomer, S. Sansone, P. Wilson, M. Franklin, A. Byon-Wagner, R. Van Berg, J. Wacker, W. Kononenko, Katherine Schultz, D. Shuman, W. C. Wester, L. Sadler, Ashutosh Kotwal, R. Schmitt, C. R. Hall, J. Guimaraes da Costa, J. Kraus, D. Tousignant, M. Brozovic, D. W. Gerdes, R. Silva, G. Veramendi, T. Vickey, D. Khazins, T. Jacobi, Kevin Burkett, Jochen Jens Heinrich, F. Ukegawa, Shin-Shan Yu, Peter Wittich, P. Tamburello, M. H. Kirby, W. J. Robertson, W. Bokhari, W. Orejudous, R. Weidenbach, J. M. Niczyporuk, Avraham Yagil, R. Snihur, R. L. Wagner |
Rok vydání: |
2004 |
Předmět: |
|
Zdroj: |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 526:249-299 |
ISSN: |
0168-9002 |
Popis: |
The Central Outer Tracker is a large cylindrical drift chamber constructed to replace Collider Detector at Fermilab's original central drift chamber for the higher luminosity expected for Run 2 at the Fermilab Tevatron. The chamber's drift properties are described in the context of meeting the operating requirements for Run 2. The design and construction of the chamber, the front-end readout electronics, and the high-voltage system are described in detail. Wire aging considerations are also discussed. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|