Autor: |
Vikrant Gupta, Sandip Gajjar, Rasesh Dave, B. Raval, Amit Patel, Dishang Upadhya, Hitesh Dhola, Ujjwal Baruah, Kush Mehta, Np. Singh, Niranjan Goswami, Aruna Thakar |
Rok vydání: |
2019 |
Předmět: |
|
Zdroj: |
2019 International Conference on High Voltage Engineering and Technology (ICHVET). |
DOI: |
10.1109/ichvet.2019.8724245 |
Popis: |
Mega watt particle accelerators like Neutral Beam Injectors draw electrical power for Plasma formation, Ion Extraction at elevated potential of ~100kV, infact the water cooling lines, gas feed lines are also floating at 100kV. Usually power supplies, hydraulic/gas feed station of typical Injector are placed in a separate building/location. In such a scenario, large coaxial transmission lines are used to support power transport, hydraulic & gas feed lines, providing electrical isolation of 100kV. This paper presents electrostatic analysis for the complex configuration of large transmission line. Specially designed profiles to provide electrical isolation within permissible limits of electric stress. Further HVDC test results showing behaviour of Transmission line over longer exposure of 3600s are also presented. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|