Kurzfristige Ergebnisse (2 bis 5 Jahre) der Hydroxylapatit-beschichteten Hüftendoprothesen vom Typ Furlong
Autor: | Meyer Hj, Messler Hh, Koch Fw, Wagner U |
---|---|
Rok vydání: | 2008 |
Předmět: |
musculoskeletal diseases
Bony tissue medicine.medical_specialty Revision arthroplasty business.industry Chirurgie orthopedique medicine.medical_treatment Aseptic loosening Prosthesis Hip replacement (animal) Surgery Orthopedic surgery medicine Orthopedics and Sports Medicine business Total hip arthroplasty |
Zdroj: | Zeitschrift für Orthopädie und ihre Grenzgebiete. 131:562-567 |
ISSN: | 1438-941X 0044-3220 |
Popis: | The short term clinical and radiological results of a hydroxyapatite-coated hip prosthesis with bonding osteogenesis on the hydroxyapatite ceramic and bony tissue reaction had to be studied. 233 patients who had hip replacement were followed up for two to five years and assessed radiologically and by the Merle D'Aubigne rating. Primary total hip arthroplasty as well as revision arthroplasty show sufficient clinical results. Tight pain and aseptic loosening of the stem did not occur. Hydroxyapatite-coating and contour for the Furlong hip prosthesis show a reliable short term anchorage. |
Databáze: | OpenAIRE |