Laboratory and field investigation of the effect of geogrid-reinforced ballast on railway track lateral resistance
Autor: | Mohammad Hosein Babaei, Jabbar Ali Zakeri, Morteza Esmaeili |
---|---|
Rok vydání: | 2017 |
Předmět: |
Ballast
Engineering Deformation (mechanics) business.industry 0211 other engineering and technologies 02 engineering and technology Welding Structural engineering Geotechnical Engineering and Engineering Geology Track (rail transport) law.invention Geogrid Vibration Buckling law 021105 building & construction General Materials Science Geotechnical engineering Geosynthetics business 021101 geological & geomatics engineering Civil and Structural Engineering |
Zdroj: | Geotextiles and Geomembranes. 45:23-33 |
ISSN: | 0266-1144 |
DOI: | 10.1016/j.geotexmem.2016.11.003 |
Popis: | Continuous welded rail (CWR) tracks have particular advantages over common tracks with jointed rails such as increased ride comfort, reduced noise and vibration and decreased maintenance costs due to the removal of joints in rail connections. Alternatively, some complications associated with CWR tracks, for instance increased lateral forces, are the main reason of track buckling and its subsequent lateral deformation. These problems are usually more severe in curved tracks. In order to overcome the large lateral forces caused by temperature deviations of CWR tracks which results in railway vehicle instability, the ballasted track lateral resistance should be improved. Among the various methods proposed in this area, no specific study has been carried out on the effect of geogrid reinforcement on ballasted track lateral resistance. Thus, the present research was allocated to investigating the effect of geogrid on the lateral resistances of both single tie and track panel via laboratory and field tests. In this regard, at the first stage, the ballast layer was reinforced with various number of geogrid layers, the effect of which was investigated by conducting the single tie push test (STPT) in the lab environment to assess the optimum number of geogrid layers and their installation levels along the ballast layer thickness. Afterwards, a test track was executed in the field including various sections which were reinforced in the same way as the lab tests. Consequently, many STPTs and track panel displacement tests (TPDTs) were accomplished. As a result, the STPTs in the lab and field confirmed more than 31% and 42% increase in single tie lateral resistance for ballast layers reinforced respectively with one and two geogrid layers, while these values were reached to 29% and 40% in the case of TPDT. |
Databáze: | OpenAIRE |
Externí odkaz: |