EVALUATION OF STATIC PRESSURE DROPS AND PM10 AND TSP EMISSIONS FOR MODIFIED 1D-3D CYCLONES

Autor: R. V. Baker, Greg A. Holt, S. E. Hughs
Rok vydání: 1999
Předmět:
Zdroj: Transactions of the ASAE. 42:1541-1548
ISSN: 2151-0059
DOI: 10.13031/2013.13318
Popis: Five modifications of a standard 1D3D cyclone were tested and compared against the standard 1D3D design in the areas of particulate emissions and static pressure drop across the cyclone. The modifications to the 1D3D design included a 2D2D inlet, a 2D2D air outlet, a D/3 trash exit, an expansion chamber with a D/3 trash exit, and a tapered air outlet duct. The 1D3D modifications that exhibited a significant improvement in reducing both PM10 and total suspended particulate (TSP) emissions were the designs with the 2D2D inlet and air exhaust combined with either the conical D/3 tail cone or the expansion chamber. In reference to the standard 1D3D cyclone, the average reduction in PM10 emissions was 24 to 29% with a 29 to 35% reduction observed in TSP emissions. The modifications with the tapered air outlets did not show any significant improvements in controlling PM10 emissions. However, the modification with the tapered air outlet/expansion chamber combination exhibited statistical significance in reducing TSP emissions by 18% compared to the 1D3D cyclone. All modifications tested exhibited lower static pressure drops than the standard 1D3D.
Databáze: OpenAIRE