Popis: One source of radiation is X-ray aircraft, which utilization must pay attention to safety aspects. Room design is the first step that must be done before the operation of X-ray aircraft. Radiology Unit Kasih Ibu Kedonganan Hospital operates an X-ray aircraft with specifications of 250 kV-85 mA, needs to be tested for radiation exposure which is an integral part of the verification of radiation protection. Test for radiation exposure at least once a year. The purpose of the installation room design is to ensure that workers or the general public around the plant receive radiation exposure that is smaller than the applicable dose limit value (DLV), by the radiation safety provisions that refer to the Decree. BAPETEN No. 7 of 2009 concerning Radiation Safety in the use of radiographic equipment. This study will test exposure to room wall shields associated with radiation workers and the general public. The results showed that all walls A, B, C, D, and E could still completely weaken the rate of X-ray radiation. The highest radiation dose detected on wall B is the primary wall for the Buky stand examination.