Fire risk assessment of cable bridges for installation of firefighting facilities
Autor: | Kyu Won Kim, Jung Hyun Yun, Moon Ok Kim, Moon Kyum Kim |
---|---|
Rok vydání: | 2020 |
Předmět: |
040101 forestry
Vulnerability General Physics and Astronomy Firefighting 020101 civil engineering 04 agricultural and veterinary sciences 02 engineering and technology General Chemistry Building and Construction Fire risk Bridge (nautical) 0201 civil engineering Girder Assessment methods Forensic engineering 0401 agriculture forestry and fisheries Standpipe (firefighting) Environmental science General Materials Science Safety Risk Reliability and Quality Countermeasure (computer) |
Zdroj: | Fire Safety Journal. 115:103146 |
ISSN: | 0379-7112 |
DOI: | 10.1016/j.firesaf.2020.103146 |
Popis: | Cable bridges such as cable-stayed bridges and suspension bridges are supported by members such as cables, reinforced girders, and pylons. Fires on the bridge can cause structural degradation in members, which can pose a severe danger to the bridge. However, in most countermeasure standards for structures, no information regarding the installation of firefighting facilities on cable bridges is available. In this paper, a fire risk assessment method for the installation of fire hydrants and standpipe systems on cable bridges is proposed. To determine the grade of the fire hazards for these bridges, the fire risk was classified into categories, such as the likelihood of fire occurrence, fire response conditions, the vulnerability of the bridge to fire, and impact of fire on the society and economy. The degree of fire hazard was determined by assigning weightage factors to each category, and the fire risk for 70 existing cable bridges and those under construction in Korea was evaluated. Application of these results can ensure adequate fire extinguishing facilities are installed on any bridge based on its fire risk. |
Databáze: | OpenAIRE |
Externí odkaz: |