COMPARISON OF THE EFFICIENCY OF THE CLOSURE OF DEFECTS OF DURA MATER WITH HIGH-FREQUENCY ELECTRIC WELDING TO TRADITIONAL SEWING CONNECTION

Autor: Dmytro Zabolotnyi, Diana Zabolotna, Olena Kvasha
Rok vydání: 2022
Zdroj: Grail of Science. :416-418
ISSN: 2710-3056
DOI: 10.36074/grail-of-science.22.07.2022.072
Popis: A comparison of the effectiveness of closure of dura mater defects in the surgical removal of tumors of the frontal sinuses with intracranial snvaiding by methods of high-frequency electric welding of tissues and traditional sutures. A comprehensive assessment of methods by a group of indicators for both direct surgery and rehabilitation period was used. Significant advantages of high-frequency bipolar electric welding in comparison with traditional seam connection are shown.Usage of biological welding contributes to a significant reduction of intra- and postoperative complications, shortening the operation time, reduced duration of postoperative treatment compared to traditional methods.
Databáze: OpenAIRE