Investigations of uncertainties from hot water flowmeters using laser Doppler velocimetry
Autor: | J.-F. March |
---|---|
Rok vydání: | 1996 |
Předmět: | |
Zdroj: | Flow Measurement and Instrumentation. 7:211-214 |
ISSN: | 0955-5986 |
DOI: | 10.1016/s0955-5986(96)00014-3 |
Popis: | Electromagnetic flowmeters will be used as working standards for determining volumetric flowrates for hot water. Flowmeters for hot water can be calibrated by the well-known mass-time method only up to 100°C. But the district heat suppliers are greatly interested in flowrate measurements at higher temperatures in order to exactly calculate the delivered heat energy. The described one-point relative method using LDV is a time-saving procedure and allows the determination of the metrological performance of flowmeters as a function of flowrate and temperature above 100°C. The relative uncertainties in the determination of the flowrates are about 0.2%. |
Databáze: | OpenAIRE |