Autor: |
Constantine N. Manikopoulos, E.S.F. Hou, Nathaniel J. McCaffrey, Jun Li, Walter F. Kosonocky, Michael B. Kaplinsky, Nuggehalli M. Ravindra |
Rok vydání: |
2002 |
Předmět: |
|
Zdroj: |
Proceedings of the IEEE International Symposium on Industrial Electronics. |
DOI: |
10.1109/isie.1995.496626 |
Popis: |
Multi-wavelength imaging pyrometer (M-WIP) is presented for remote sensing of temperature profiles of targets with unknown emissivity. A software package was developed for calibration and real-time M-WIP measurements. An experimental 7-filter line-sensing M-WIP system was implemented with a 320/spl times/122-element PtSi IR-CCD imager. The M-WIP system was calibrated against a commercial blackbody source over a temperature range from 450/spl deg/C to 900/spl deg/C. The signal processing included background subtraction and compensation for variation of dark current with detected signal and nonlinearity of IR imager response. Initial M-WIP measurements demonstrated real-time temperature resolution /spl Delta/T of /spl plusmn/1/spl deg/C for blackbody target over temperature range from 600/spl deg/C to 900/spl deg/C. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|