Inter-observer reproducibility and intra-observer repeatability in 99mTc-pyrophosphate scan interpretation for diagnosis of transthyretin cardiac amyloidosis
Autor: | Hicham Skali, Sarah Cuddy, Marcelo F. Di Carli, Mi-Ae Park, Vasvi Singh, Ron Blankstein, Viviany R. Taqueti, Marie Foley Kijewski, Sharmila Dorbala, Alexandra Taylor, Rodney H. Falk |
---|---|
Rok vydání: | 2020 |
Předmět: |
Reproducibility
biology business.industry Inter observer reproducibility Coefficient of variation Concordance Repeatability 030204 cardiovascular system & hematology Intra observer 030218 nuclear medicine & medical imaging 03 medical and health sciences Transthyretin 0302 clinical medicine Cardiac amyloidosis biology.protein Medicine Radiology Nuclear Medicine and imaging Cardiology and Cardiovascular Medicine business Nuclear medicine |
Zdroj: | Journal of Nuclear Cardiology. 29:440-446 |
ISSN: | 1532-6551 1071-3581 |
DOI: | 10.1007/s12350-020-02353-4 |
Popis: | The purpose of this study was to determine the inter- and intra-observer variability in 99mtechnetium-pyrophosphate (99mTc-PYP) scan interpretation for diagnosis of transthyretin cardiac amyloidosis (ATTR). Our study cohort comprised 100 consecutive subjects referred for 99mTc-PYP imaging based on clinical suspicion of ATTR cardiac amyloidosis. Myocardial 99mTc-PYP uptake was assessed by both visual (comparison of myocardial to rib uptake) and semi-quantitative (heart-to-contralateral lung uptake ratio, H:CL) methods. Twenty scans were analyzed twice, at least 48 hours apart, by each of two independent observers. Patients with visual scores of ≥ 2 on planar imaging as well as myocardial uptake on SPECT/CT were classified as ATTR positive. Diagnosis of ATTR by visual 99mTc-PYP grade was perfectly reproducible [concordance: positive and negative scans 100% (53/53 and 47/47, respectively). Both inter- and intra-observer correlations for H:CL ratio (r2 = 0.90, 0.99 (Observer 1) and 0.98 (Observer 2), respectively) and repeatability values on Bland–Altman plots were excellent. The coefficient of variation (%) for Observers 1 and 2 was 3.21 (2.14 to 4.29) and 7.49 (4.95 to 10.09), respectively. In addition, there was 100% concordance in positive and negative scan interpretation by visual grading between novice CV imagers (< 3 years’ experience) and an experienced CV imager (10 years’ experience). This study showed excellent inter-observer reproducibility and intra-observer repeatability of 99mTc-PYP visual scan interpretation and H:CL ratio for diagnosis of cardiac ATTR amyloidosis. Cardiac ATTR amyloidosis can be diagnosed reliably using 99mTc-PYP SPECT/CT by novice and experienced CV imagers. |
Databáze: | OpenAIRE |
Externí odkaz: |