Enantioseparation of Palonosetron Hydrochloride and Its Related Enantiomeric Impurities by Computer Simulation and Validation

Autor: Katkam Srinivas, Charagondla Krishnaiah, M. Vishnu Murthy, Gautam samanta, K. Mukkanti, Ramesh Kumar, Kodithyala Jyothirmayi
Rok vydání: 2011
Předmět:
Zdroj: American Journal of Analytical Chemistry. :437-446
ISSN: 2156-8278
2156-8251
DOI: 10.4236/ajac.2011.24053
Popis: A rapid, simple and single stereo selective high-performance liquid chromatographic (HPLC) method was developed and validated for enantiomers of palonosetron hydrochloride (PALO) and its process related chiral impurities. A computer simulating software was used for the development of chiral method. The developed method was able to separate not only the enantiomers of palonosetron hydrochloride but also its process related chiral impurities within 12 min. The chromatographic separation was carried out by normal phase chromatography using a 3 µm column of cellulose based chiral stationary phase (Chiralcel-OD 250mm × 4.6mm) with a mobile phase comprised of n-hexane: ethanol: methanol: heptafluoro butyric acid: diethyl amine (70:15:15:0.05:0.1, v/v) at a flow rate of 1.0 mL/min. The effects of additive concentration as well as nature of polar organic modifier, flow rate, and temperature on enantioselectivity were investigated. The limit of detection (LOD) and limit of quantification (LOQ) of the palonosetron isomers and its related chiral impurities were found to be in the range 0.06-0.10 µg/mL and 0.14 - 0.24 µg/mL respectively. The method showed excellent linearity (R2 > 0.998) over a range of 0.14 to 1.125 µg/mL. The percentage recovery of the isomers in bulk drug samples ranged from 87.0 to 116.0.
Databáze: OpenAIRE