Stress-reinjection 201TI scintigraphy without redistribution imaging
Autor: | Ernest K. J. Pauwels, E. E. van der Wall, Aaf F. M. Kuijper, A. V. G. Bruschke, M. G. Niemeyer, B. L. F. Van Eck-Smit, A. H. Zwinderman |
---|---|
Rok vydání: | 1996 |
Předmět: |
Bypass grafting
medicine.diagnostic_test business.industry chemistry.chemical_element General Medicine Scintigraphy medicine.anatomical_structure chemistry Medicine Thallium Radiology Nuclear Medicine and imaging Derivation Wall motion Nuclear medicine business Prospective cohort study Perfusion Artery |
Zdroj: | Nuclear Medicine Communications. 17:659-668 |
ISSN: | 0143-3636 |
DOI: | 10.1097/00006231-199608000-00003 |
Popis: | Reinjection of thallium-201 (201Tl) improves the detection of myocardial ischaemia in approximately 50% of irreversible defects present on 3 h redistribution images. Additional reinjection studies, however, may limit the capacity of the nuclear laboratory and they are not patient-friendly Previous studies have suggested that only severe persistent defects with less than 50% of maximal 201Tl uptake are irreversibly damaged, with little chance of recovery following coronary artery bypass grafting (CABG). We examined the ability of a modified stress-reinjection protocol without redistribution imaging to predict subsequent improvement in myocardial perfusion post-CABG. Thirty-seven patients underwent quantitative planar stress/3 h reinjection 201Tl scintigraphy before and after uncomplicated CABG. After stress, segments were classified as normal (> or = 75% maximum 201Tl uptake), moderate defect (50-75%) or severe defect ( or = 75%), partially improving moderate defect (increase > or = 10% but or = 10% but < 50%), persistent moderate defect (< 10% increase) or persistent severe defect (< 50% initial uptake with < 10% increase). Scintigraphic classification was compared with left ventricular wall motion and post-operative classification. Of 336 initial stress defects, 264 (79%) were moderate defects and 72 (21%) were severe defects. After reinjection, 146 (55%) moderate defects normalized, 25 (9%) improved partially and 93 (35%) persisted. Nineteen (26%) severe defects normalized, 33 (46%) improved to become moderate defects, 7 (10%) improved only slightly and 13 (18%) persisted. Post-CABG, 201T1 uptake was normal in 123 of 146 (84%) completely normalizing moderate defects, 15 of 25 (60%) partially improving moderate defects, 53 of 93 (57%) persistent moderate defects, 11 of 19 (58%) completely normalizing severe defects and 13 of 33 (39%) partially improving moderate defects. None of the partially improving severe defects or persistent severe defects normalized. The sensitivity and specificity of detection of viability with pre-CABG stress-injection scintigraphy were 66% and 72% respectively, with pre-CABG wall motion 80% and 40% respectively, whereas in combination they resulted in a sensitivity and specificity of 94% and 70% respectively. We conclude that stress/3 h reinjection without redistribution imaging is a clinically feasible method for predicting myocardial 201T1 uptake post-CABG. The severity of defects and the pattern of change of uptake after stress-injection are related to the likelihood of normal 201T1 uptake post-CABG. Severe defects after reinjection are very unlikely to recover. |
Databáze: | OpenAIRE |
Externí odkaz: |