Popis: Introduction: The application of external fixation devices consists of wires insertion through the skin and soft tissue to the bone. We examined the possible analgesic effect of stimulating an acupoint by the fixation wires which mimics the acupunctures treatment. Material and methods: retrospective work. Between 2015 to 2018 107 patients were treated with an external fixation for a tibial fracture. 33 patient files were found to be eligible for the review. Patients were retrospectively divided into two groups: the study group included patients with a wire inserted through the ST36 (Zu San li) acupoint location, the control group had the wire inserted elsewhere. Patient's record was reviewed for 5 days following surgery. Data collected included analgesic consumption and pain level recorded on a visual analog scale (VAS). Results: 33 patients were included in the review. 20 patients in the study group and 13 served as the control group. In the study group VAS average was Mean (M)=1.4853 ± 1.30 while in the control group M=2.3885± 1.77 with no statistical relevance (P>0.05). Only on day 4 the study group had less pain than the control: M=0.40 ± 0.843, versus M=2.57 ± 2.149 (Mann=Whitney Z= -2.413, P